To view Sachse's current zoning
map,
click here.
Please
contact the Community Development Department with any questions that you
may have at 972.675.1633.
Current
Residential Zoning Abbreviations:
R-39 - Single Family Residential (39,000 sq. ft. lot)
R-15 - Single Family Residential (15,000 sq. ft. lot)
R-12 - Single Family Residential (12,000 sq. ft. lot)
R-10 - Single Family Residential (10,000 sq. ft. lot)
R-8.4 - Single Family Residential (8,400 sq. ft. lot)
R-7.8 - Single Family Residential (7,800 sq. ft. lot)
R-7.2 - Single Family Residential (7,200 sq. ft. lot)
Older
Residential Zoning Abbreviations:
R-5 - Single Family Residential (8,500 sq. ft. lot)
R-4 - Single Family Residential (10,000 sq. ft. lot)
R-3 - Single Family Residential (12,000 sq. ft. lot)
R-2A - Single Family Residential (10,000 sq. ft. lot)
R-2 - Single Family Residential (15,000 sq. ft. lot)
R-1 - Single Family Residential (39,000 sq. ft. lot)
P.D.
- Planned Development
C-1 - Neighborhood Shopping District
C-2 - General Commercial District
I-1 - Restricted Manufacturing/Warehousing
I-2 - General Industrial District
F - Flood Plain District
AG - Agricultural District
SP - Special Use Permit
Preliminary
Plat Review Process
The
Plan Review Committee reviews the Preliminary Plat with the
representatives of the utility companies. The Plan Review Committee
consists of the Community Development Director, Director of Public Works,
Building Official and the Fire Marshall. Plans are also forwarded to
the City's Engineer for review. Six (6) copies of 24" x
36" blue line prints are required. Comments are returned to the
applicant as to deficiencies on the Preliminary Plat. The applicant
has the opportunity to correct the plans. Once the plans are
corrected, return to the Community Development Department two (2) size
24" x 36" blue line copies of the corrected folded Preliminary
Plat, and twenty (20) 11" x 17" reduced copies of the corrected
Preliminary Plat, and a letter addressing each comment by the Plan Review
Committee and the City's Engineer.
All
materials must be submitted at least three weeks prior to desired Planning
and Zoning meeting date.
The
Preliminary Plat is then forwarded to the Planning and Zoning Commission
for consideration. If the Preliminary Plat is approved by the
commission, conditional approval shall be effective for one year.
Final
Plat Review Process
The
Plan Review Committee reviews the Final Plat. The committee consists
of the Community Development Director, Director of Public Works, Building
Official, Fire Marshall and a representative from the Police Department.
Plans are also forwarded to the City's Engineer for review. Six (6)
copies of 24" x 36" blue line prints are required.
Comments are returned to the applicant as to deficiencies on the Final
Plat. The applicant has the opportunity to correct the plans.
Once the plans are corrected, return to the Community Development
Department two (2) blue line copies of the corrected folded Final Plat at
24" x 36" size, and twenty (20) 11" x 17" reduced
copies of the corrected Final Plat, and a letter addressing each comment
by the Plan Review Committee and the City's Engineer.
All
materials must be submitted at least three weeks prior to desired Planning
and Zoning meeting date.
The
Final Plat will then be forwarded to the Planning and Zoning Commission
for consideration.
Click here
for fees. |